Logo EAS-TB

Revision Covers APT

Fire resistance 30 min. (fire retardant) / 90 min. (fire resistant)

 

Standversion Unterputz teilversenkbar einflügelig
Standversion Unterputz teilversenkbar zweiflügelig
Wandversion Unterputz teilversenkbar einflügelig
Wandversion Unterputz teilversenkbar zweilügelig

 

 

Execution
 

  • For partially rectractable installation
  • Floor-standing (S-UPT-TM) and wall-hanging version (W-UPT-TM)
  • Different frame depths available  (101 - 250 mm)
  • Min. installation depth 100 mm
  • Max. wall projection 150 mm

 

Min. / Max. Sizes – Exterior Dimensions [mm]  

 

Floor-standing version (S-UPT-TM)

 

  • Single-leaf execution: H 355 x W 390 to H 2.500 x W 960
  • Double-leaf execution: H 355 x W 690 to H 2.500 x W 1.800
     

Wall-hanging version (W-UPT-TM)

 

  • Single-leaf execution: H 355 x W 390 to H 2.500 x W 960
  • Double-leaf execution: H 355 x W 690 to H 2.500 x W 1.670

 

Colours and Decors

 
Choose from an almost unlimited amount of colours and surfaces for your retractable in-wall revision door.

 

 

Wall Types
 

  • Installation shafts from a massive construction like masonry, concrete, or reinforced concrete, with at least 100 mm thickness
  • Installation shafts from stud partition walls acc. to DIN 4102-4 with a double-sided panelling (with two at least 12,5 mm thick non-combustible fire protection panels on both sides) according to DIN 18180
  • Installation shafts from stud partition walls acc. to DIN 4102-2 with single panelling (with two at least 20 mm thick non-combustible gypsum bound building panels)
  • Steel supports clad on each side with non-combustible building panels as part of an installation shaft wall

 

Installation / Mounting Aid
 

  • User-friendly installation
  • Detailed installation manual is part of the delivery
  • Fixing material included in delivery
     

 